MVM-020-QAH Magnetic Flow Meter | Hastelloy C® Magnetic Flow Meter Hastelloy C [1 .. 20 lpm, 4 .. 20 mA]

The MAG-VIEW™ series operate on the magnetic inductive principle. The complete absence of moving parts, its interference free operation and the insensitivity with contaminated liquids, makes this magnetic flow meter the perfect solution even in compact machines with cramped confines.
Water like liquids
Frequenz & 4..20mA
MVM-020-QAH Magnetic Flow Meter | Hastelloy C®
MVM-020-QAH Magnetic Flow Meter | Hastelloy C®
MVM-020-QAH Magnetic Flow Meter | Hastelloy C®

MVM-020-QAH Magnetic Flow Meter | Hastelloy C®

Magnetic Flow Meter Hastelloy C [1 .. 20 lpm, 4 .. 20 mA]

The MAG-VIEW™ series operate on the magnetic inductive principle. The complete absence of moving parts, its interference free operation and the insensitivity with contaminated liquids, makes this magnetic flow meter the perfect solution even in compact machines with cramped confines.
Online-Preis ab:
$640,50
Vollständig auf Lager
Versand erfolgt innerhalb von 2 Tagen
Sie können Ihre Bestellung fortsetzen, aber die gewünschte Menge ist nicht vorrätig, das sind 3 Stück. Die neue Lieferzeit wird bei der Bestellung angegeben.
Es sind nur noch 3 Produkte auf Lager. Bitte passen Sie die Menge an, wenn Sie mit Ihrer Bestellung fortfahren möchten

Mengenrabatte auf den Preis

Menge
5+
10+
Rabatt
10%
25%
Preis
€576,45
€480,38

Flow ranges

This magnetic flow meter is suitable to measure flows of water and other conductive liquids within a flow range of 1 .. 20 lpm.

ModelMinMaxoutput signal starts
MVM-020-QA1 l/min20 l/min~ 0.25 l/min

Scope of delivery

  • Magnetic Flow Meter
  • Calibration certificate
  • Packing box
  • MAG-VIEW Manual
  • (optional) instrument cable

Eigenschaften von MVM-020-QAH Magnetic Flow Meter | Hastelloy C®

  • Makes liquid flows visible by
    1. Pulse output
    2. Analog output (4..20 mA)
    3. Blinking LED (green)
  • No mechanical wear
  • No moving parts
  • Ease of mounting and operation
  • Mounting in any position
  • Free pipe cross section
  • No additional pressure drop
  • Fast response (<100 ms)
  • Insensitive with contaminated liquids
  • Ideal solution for interference free operation combined with a long-life cycle
  • Can be used in areas where flow sensors with moving parts cannot be applied
  • Wide independence to the inlet and outlet pipe creates the advantage to be able to install in compact machines with cramped confines

Technische Spezifikationen

Mess- / Regelungssystem

Durchflussbereich
1 … 20 l/min
Genauigkeit
±0.7 % of reading ±0.3 % of range
(incl. factory calibration certificate; test conditions: water 23°C)
Wiederholgenauigkeit
1 % FS
Max. Durchflussmenge
25 l/min
Temperaturbereich
Ambient temperature: -15..60°C
Storage temperature: -15..60°C
Betriebsdruck
10 bar(a) (20 °C), 8 bar(a) (40 °C), 6 bar(a) (60 °C)
Nennweite
DN 8
Durchfluss- / Alarmanzeige
Green LED: flow proportional flashing
Signaloutput ab
~ 0.1 l/min
Medium
Water and other conductive liquids
(minimum conductivity of 20 μS/cm)
Mediumtemperatur
± -15.. 80 °C (not freezing)
Bereich
1:20
Reaktionszeit (Sensor)
< 100 ms

Mechanische Teile

Material (benetzte Teile)
Housing: ABS
Electrodes: Hastelloy C®
Process connections: PVDF
Measuring pipe: PVDF
Grounding rings: Hastelloy C®
Prozessanschlüsse
G1/2'' BSP male thread
Dichtungen
EPDM
Schutzklasse
IP65

Elektrische Eigenschaften

Stromversorgung
12 .. 24 Vdc ±10%
Max. Leistungsaufnahme
Typical 1.1 W, max. 3.6 W
Elektrische Schutzmaßnahmen
short-circuit proof,
protected against polarity reversal
Analogausgang
4 … 20 mA
Frequenzausgang
Pulse rate / K-factor : 1000 pulses/l
Resolution : 1,0 ml/pulse
Signal shape : Push-Pull
Signalform
Square wave signal, duty cycle 50:50 (Push-Pull)
Signalstrom
Max. 100 mA
Pin-Belegung
PIN 1: +UB
PIN 2: Analog output
PIN 3: GND
PIN 4: Frequency output
Elektrischer Anschluss
4-pin-plug M12x1

Product details

Electrical connection
Electrical connection
Dimensions MVM-xxx-QA
Dimensions MVM-xxx-QA
Pressure drop MVM-020-QA
Pressure drop MVM-020-QA


Anwendungen

The fields of application for this magnetic flow meter are diverse:

  • Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media
  • Sensor is intended for continuously measuring of flow rates or for dosing / batching of electrically conductive liquids with a minimum of 20µS/cm
  • Water distribution
  • Chemical feed
  • Measuring of cooling water, measuring of waste water
  • Cleaning Industry: Dosing of detergents and other additives
  • Agriculture: dosing of water, fertilizer, fungicides and pesticides, measuring of water and liquid feed supplements
  • Exhaust Gas Cleaning: Dosing of AdBlue